Niros RX8008
Programmierungsmenü
Geräte mit 8 Schleifen
FILENAME Oppermann-Telekom                                                                DATE Frl 5/5—2000     p 1
GENERAL PARAMETERS
System  ZVEI Group tone A Repeat tone R
Tone length 70 mS  Fast 1. Tone 0FF Default vol 3
LS hold time 14.9 s Max LS on time 180.1s  Default Ch 0
Record delay 0.0 s Rec hold time 14.9s Tone Ctrl.  NO
Default scan NO Scanning delay 98.3 ms  Manuel scan NO
Record time  15s Record mode MULTI Manuel Pwr YES
Alarm repeat 2 min P-timer step 5 min  Default LS NO
Out-Of-Range NONE Warning delay 0 min Keep warn NO
 
CHANNELS
 
Frequency
LS SCAN DEC-A DEC-B  
Frequency
LS SCAN DEC DEC-B
CH-0
86375000 Hz
YES YES 1234 1234
CH-8
Hz
NO  NO  ---- ----
CH-1
87155000 Hz
1234 1234 1--- 1---
CH-9
Hz
NO NO ---- ----
CH-2
Hz
NO NO 1234 1234
CH-A
Hz
NO NO ---- ----
CH-3
Hz
NO NO 1234 1234
CH-B
Hz
NO NO ---- ----
CH-4
Hz
NO NO 1234 ----
CH-C
Hz
NO NO ---- ----
CH-5
Hz
NO NO 1234 ----
CH-D
Hz
NO NO ---- ----
CH-6
Hz
NO NO ---- ----
CH-E
Hz
NO NO ---- ----
CH-7
Hz
NO NO ---- ----
CH-F
Hz
NO NO ---- ----
Ref. 5/6.25
FUNCTION
Company name  OPPERMAN Manuel LS  YES
User name  FFBRUNN Key beep ON
Fallback time 16.8 s Volume status NO
Display swap 1.8 s Channel status NO
Menu Language GERMAN
Menu Menu
1 F-FBRUNN Status 9  - Free
2 ALARME Alarms 10  - Free
3 ABSPIEL Playback record 11  - Free
4 KANAL Channel selection 12  - Free
5 SCAN Scanning on/off 13  - Free
6 STAERKE Volume 14  - Free
7 STILL Silent mode 15  - Free
8 VIBRA Disable vibrato 16  - Free
 
 FILENAME : FBRUNN DATE :                                          Fri 5/5—2000                     p 2
 TONE DECODER 1
Decoder A
Decoder B
Code 16330----------- Code 16334-----------
Grp/Pos ---------------- Grp/Pos ----------------
Ctrl ---------------- Ctrl ----------------
Text GRUPPE-1 Text KATS-ZUG
Start recording  YES Activate Led  YES Open LS  YES

 
Seq. 1 Seq. 2 Seq. 3 
Alarm tones
Vibrator YES NO YES  
Tone
Time
Pause
Alarm tones YES YES YES
Step 1
2600 Hz
500 ms
 250 ms
Ovr. Silent  NO NO YES
Step 2
2200 Hz
 500 ms
250 ms
Volumelevel MAX MAX MAX
Step 3
1800 Hz
 500 ms
250 ms
Rep time (s) 3.0 3.0 3.0
Step 4
1400 Hz
 500 ms
250 ms
 
Stand : Mai 2000